ULTRASONIC WELDING
Power Supply for Automation
The ultrasonic generator, t series of Covonics,
is designed with PLL circuit that enables to set delay time, weld time, hold time on the front panel and Horn down function is Internalized. It can be combined power supply and actuator without PLC.
Key Features
Internalization of System Protection
Monitoring (SPM)
Monitoring (SPM)
1) Phase Changing 2) Over Voltage
3) Over Current 4) Heating Overload
5) Power Overload
3) Over Current 4) Heating Overload
5) Power Overload
Maintains converter amplitude by regulating for variances in the line voltages and Maintains converter amplitude over the full range of rated power.
Autotune and Frequency Memory
Automatically adjust frequency within error range for each frequency.
Updates horn frequency memory at the end of each weld and memory frequency can be reset by external reset.
Updates horn frequency memory at the end of each weld and memory frequency can be reset by external reset.
Selectable ramp up time to reach the max amplitude
Provides four starting ranges. Select Start allows the Power Supply to ramp up amplitude at different rates to accommodate different horn and load requirements. 10, 30, 80, 100 ms
Bar graph on Front panel- During a weld cycle, shows the true percentage of ultrasonic power in use.
Digital amplitude change
1) Front Panel 2) External Source
Auto seek
Track Horn frequency at low amplitude and store in memory
1) Seek on power-up
2) External Control
3) Seek by Test key on Front panel
4) Checks horn frequency once each minute
1) Seek on power-up
2) External Control
3) Seek by Test key on Front panel
4) Checks horn frequency once each minute
Provides interface signals for Automatic product line
1) Weld on - Digital output
2) Alarm out - Digital output
3) External Run - Digital input
4) External Reset / External Seet
- Digital input
5) External Amplitude Control
- Analog input
6) Power on status - Digital output
7) Solenoid valve for horn down cylinder
- Digital output
8) Solenoid valve for cooling
- Digital output
9) External E-stop signal - Digital input
2) Alarm out - Digital output
3) External Run - Digital input
4) External Reset / External Seet
- Digital input
5) External Amplitude Control
- Analog input
6) Power on status - Digital output
7) Solenoid valve for horn down cylinder
- Digital output
8) Solenoid valve for cooling
- Digital output
9) External E-stop signal - Digital input
Frequency | 20kHz | 30kHz | 35kHz | 40kHz |
---|---|---|---|---|
Power output | 2000W | 1500W | 1500W | 800W |
Max.current | 13amps | 20amps | 20amps | 10amps |
Line voltage | 200~240V AC 50/60Hz, 1Ø | |||
Wdight | 7Kg | |||
Size | 305mm * 145mm * 470mm |
Power supply
C20W10 20kHz 1000WC20W20 20kHz 2000W
C30W15 30kHz 1500W
C35W15 35kHz 1500W
C40W08 40kHz 800W
Cable
Start cableRF cable (BNC)
RF cable (MS)
I/O cable(D-sub 9)
I/O cable(D-sub 24)
Converter
CM20 20kHz (MS contact)CB20 20kHz (BNC contact)
CJ20 20kHz (ball contact)
CM30 30kHz (MS contact)
CB30 30kHz (BNC contact)
CM35 35kHz (MS contact)
CB35 35kHz (BNC contact)
CM40 40kHz (MS contact)
CB40 40kHz (BNC contact)
|
20kHz | 30kHz | 35kHz | 40kHz |
---|---|---|---|---|
Al 1:0.6 | Ο | - | - | Ο |
Al 1:1 | Ο | - | - | Ο |
Al 1:1.5 | Ο | - | - | Ο |
Al 1:2 | Ο | - | - | Ο |
Ti 1:1 | Ο | Ο | Ο | Ο |
Ti 1:1.5 | Ο | Ο | Ο | Ο |
Ti 1:2 | Ο | Ο | Ο | Ο |